Metallurgical failure analysis of a welded drive beam of a vibrating screen
A drive beam from a vibrating screen fractured in service. • A critical stress concentrator in a weld detail was the origin of the fracture. • Crack propagated by a high cycle fatigue mechanism. • The use of S-N curves for equipment operating in a giga-cycle regime was validated.